The Magazine Dedicated to the Next Generation of Test Systems that Harness the Power of Ethernet



Products

 
 

 


Power Meters
 

LXI
The Agilent N8262A P-Series Power Meter is designed for seamless operation with widely used standards like Ethernet, web browsers, and IVI drivers and integrates easily to work with existing test assets. The 1U, LXI class C-compliant unit supports LAN-based automated measurements of peak, peak-to-average ratio, and average power.

 

The modular power meter has a sampling rate of 100 MS/s and performs time and CCDF statistical measurements. Users can program the N8262A with various programming languages, including Agilent VEE, LabVIEW, LabWindows, C, C++, and MATLAB. N1918A Power Analysis Manager software is optional.

 

The meters are code-compatible with the Agilent P-Series power meters and backward compatible with the P-Series, most E-Series, and 8480 Series power sensors.

 

Agilent Technologies
www.rsleads.com/715ee-177

 


Matrix Switching
 

LXIThe new 60-310 High-Voltage Matrix and the 60-510 LXI Low Thermal EMF Matrix are supplied with IVI, SOAP and Direct I/O drivers, and soft front panels that allow them to be controlled through any W3C compliant web browser. Each unit is contained within a 2U full-rack enclosure.

The 60-310 is a two-pole 300x2 switching matrix for hot-switching 500-VDC signals and cold-switching 1,000-VDC signals. The design uses Rhodium-plated reed relays.

The 60-510 is a 56x33 matrix capable of switching 150 VDC signals at currents up to 1 A. The matrix uses instrument-grade Ruthenium-sputtered relays to ensure a long service life while typically providing less than 2.5 mV of thermal EMF.

Pickering Interfaces
www.rsleads.com/715ee-180

 


Graphical Test Software
 

LXIInstrument Pak, an add-on to Measure Foundry™ 5.0, provides drag-and-drop graphical software to configure LXI test and measurement applications using IVI-COM drivers along with existing VISA and SCPI programs. It supports several standard instruments: function generators, oscilloscopes, DMMs, and programmable power supplies for ATE. Instrument Pak requires Measure Foundry Professional, which includes a built-in installer for easy royaltyfree distribution of executables.

Measure Foundry 5.0 features a process component for creating automated test sequences; an enhanced inspector tool; built-in text-based language; and software components such as real-time crash-safe disk recorder, scope, chart recorder, and spectrum analyzer. Version 5.0 has a formbased application design vs. a worksheet format, a library with 20 filter components, and clear separation of design mode and run mode.

Data Translation
www.rsleads.com/715ee-178

 


AC Power Management Switch
 

LXIThe The 60-200 Remote AC Power Management Switch applies AC power to any instrument or AC-powered device under exact programmatic control. A single AC supply connection to eight switched AC outlets provides power to all connected instruments. Each connection can be turned on or off including precise timing delays under programmatic control over an LXI-compliant connection or controlled completely through any W3C-compliant web browser.

The 60-200 can be programmed to power up and power down devices connected to it in any specified order. An emergency shutdown switch on the front panel also connects a remote emergency switch.

The 1U-high unit features relays specifically designed to ensure that the switching system can handle switching instruments with EMC filters that have a high inrush current.

Pickering Interfaces
www.rsleads.com/715ee-179

 

Download LXI Products PDF
 


Vector Signal Generator
 

The LXI Class C-compliant Model 2910 RF Vector Signal Generator uses specialized synthesizer technology and unique power-leveling techniques to provide fast frequency tuning, amplitude settling, and waveform switching. Features include an intuitive touch-screen graphical user interface, a 1.5-ms settling time, and interfaces for 100Base-T Ethernet, USB, and GPIB.

The 2910’s 64-MS arbitrary waveform generator supports simultaneous loading of multiple signal waveforms and 5-ms switching between them. The unit also generates a 200-MHz bandwidth RF signal from analog baseband in-phase and quadrature signals. Optional built-in signal-generation software targets mobile phone testing including GSM, GPRS, EDGE, W-CDMA, cdmaOne, and cdma2000. Users can choose between graphical or tabular methods to edit waveforms or create new ones.

Keithley Instruments
www.rsleads.com/614ee-178

 


Switching and Control Instruments


The L4400 Series of faceless switching and control instruments has a 1U-high, half-rack form factor and is LXI Class C compliant. The four switching products are the L4445A Microwave Switch/Attenuator Driver that controls external switches and attenuators, the 32-channel L4437A Form A/Form C General-Purpose Switch, the L4433A Dual/Quad 4×8 Reed Matrix, and the 40-channel L4421A Armature Multiplexer with latching armature relays.

Rounding out the series are the 64-b L4450A digital I/O with memory and a counter, the four-channel L4451A isolated D/A converter with memory, and the multifunctional L4452A with digital I/O, D/A, and totalizer input. All seven instruments include connectivity software and IVI drivers.

Agilent Technologies,
www.rsleads.com/614ee-176

 

 

Digital Power Supplies


The DLM Series Programmable DC Power Supplies feature a half-rack format and output voltages from 5 V to 600 V. The DCS Series includes 1-kW, 1.2-kW, and 3-kW programmable models in 1U and 2U full rack formats with maximum voltages from 8 V to 600 V and maximum currents from 1.7 A to 350 A.

For both series, an optional Ethernet interface provides LXI Class C compliancy, 10Base-T and 100Base-T protocols, and 16-b control and readback of voltage and current as well as additional control and communications functions. Manual control is via 10-turn front-panel potentiometers. Set-point or actual voltage or current values can be viewed on two 3.5-digit LED displays, and separate LEDs indicate remote programming, shutdown, and overvoltage protection.

Elgar Electronics,
www.rsleads.com/614ee-177

 

Download LXI Products PDF
 

 

LXI-COMPLIANT PRODUCTS

 

Agilent Technologies has expanded its selection of LXI-compliant products to 35 with the introduction of the 34980A Multifunction Switch/Measure Unit, the 34410A and 34411A 6½-digit DMMs, and the N6701A and N6702A Modular Power Supplies. These products also are part of Agilent Open, a program that ensures industry-standards-based open connectivity in hardware and software.

The 34980A Multifunction Switch/Measure Unit is a one-box solution for medium to high-density switch/measure applications in design verification, automated test, and data acquisition. The eight-slot mainframe has an optional built-in 6½-digit DMM and accommodates selections from 19 different plug-in modules. These include switching from DC to 20 GHz, digital I/O, D/A converters, and counter/totalizer functionality.

The 34410A is a 6½ digit, dual-display, benchtop digital multimeter featuring 10,000 readings/s at 5½ digits; a datalogging wizard; resistance and frequency measurement; and added LAN, USB, and GPIB connectivity. The 34411A provides up to 50,000 readings/s at 4½ digits, a 1 million reading memory, and triggering capabilities. It includes all the features of the 34410A and can be used in R&D and manufacturing environments.

The N6701A and N6702A Modular Power System Mainframes offer 600-W and 1,200-W capability, respectively. Both units accommodate one to four modules in a 1U package size. The system-ready test instrument complies with LXI Class C; offers USB 2.0, 10/100Base-T Ethernet, and GPIB interfaces as standard features; and operates remotely by connecting to its built-in Web page.

Agilent Technologies
www.rsleads.com/613ee-177

 

Download LXI-Complaint Products PDF

 
 
Microwave Synthetic Instruments

 

Agilent Technologies has introduced a family of microwave synthetic instruments that supports the U.S. Department of Defense (DoD) NxTest vision of flexible, modular, and configurable instrumentation. Synthetic instrumentation involves linking together individual hardware and software test modules to emulate standard instruments in a compact form factor. This common system architecture provides obsolescence protection by enabling the design of scalable automated test systems with the flexibility to accommodate new measurement capabilities as applications change.

The new instruments include the N8201A Downconverter, the N8221A Digitizer, the N8241A Arbitrary Waveform Generator, the N8212A Vector Upconverter, and the N8211A Analog Upconverter. All of the instruments will be LXI compliant.

The N8201A is a 26.5-GHz downconverter that provides IF output frequencies of 7.5, 21.4, and 321.4 MHz. External mixing can be used to downconvert signals up to 110 GHz. The 30-MS/s IF digitizer, the N8221A, has a 21.4-MHz IF input, a dynamic range of 80 dB, 14-b resolution, and a modulation bandwidth of 8 MHz.

The N8241A features a sampling rate of 1.25 GS/s and 15-b resolution, simultaneously. It has dual-channel, single-ended, and differential outputs with 500 MHz of instantaneous bandwidth per channel.

The 20-GHz vector upconverter, the N8212A, is a microwave source with greater than 2-GHz I/Q modulation bandwidth. It features AM, FM, and pulse modulation and multisource coherent carrier capability. The N8211A 20/40-GHz Analog Upconverter offers internal or external AM, FM, and pulse modulation capabilities along with high output power and low phase noise.
Agilent Technologies
www.rsleads.com/516ee-178

 

Download Microwave Synthetic Instruments Product PDF
 

Modular Switching Chassis

Pickering Interfaces announces the Models 60-100 and 60-101 Modular Switching Chassis that comply with Functional Class C products of the LXI standard. Model 60-100 has seven slots and Model 60-101 13 slots that can accommodate a range of the company’s 3U PXI switching modules. The 32/64-b chassis backplane is compliant with the cPCI/PXI specification.

Front-panel LEDs are provided that monitor system operation and include Power, Ready, Error, LAN, and Active. The chassis meet applicable EU directives including Low Voltage Safety EN 61010-1:1993, EMC Immunity EN 50082-1:1992, and EMC Emissions EN 55011:1991.

Models 60-100/101 are supplied with generic IVI drivers as per the standard but also can be controlled via a kernel driver. The LXI-compliant interface enables the chassis to be operated from a standard PC-Ethernet interface. Remote control is accommodated using simple cabling or the web.
Pickering Interfaces
www.rsleads.com/516ee-179

 

Download Modular Switching Chassis Product PDF

 

 


Editor's Column

Consortium Column

Articles

Products

Industry News

Subscribe

Contact Us

LXI Consortium

EE Magazine